Home » Products » cables » Potentia Cable » Medium Voltage XLPE Insulatum PVC Uatum Power Cable 3.6-6kV-26-35kV

Medium Voltage XLPE Insulatum PVC Uatum Power Cable 3.6-6kV-26-35kV

5 0 Recensiones
Availability:
quantitas;
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

1.8/3(3.6)kV,XLPE Insulated Tape armatae PVC vaginatae Power Cable

Single-core, CU/XLPE/ATA/PVC vel AL/XLPE/ATA/PVC (Tabula 17)

Conductor

Nominal

Area

Inulation Crassitudo

Proxime.Interiorem Coverage

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

10

2.0

1.2

0.5

1.8

18

390

330

500

16

2.0

1.2

0.5

1.8

19

460

360

500

25

2.0

1.2

0.5

1.8

20

580

420

500

35

2.0

1.2

0.5

1.8

21

700

480

500

50

2.0

1.2

0.5

1.8

23

840

550

500

70

2.0

1.2

0.5

1.8

24

1,080

650

500

95

2.0

1.2

0.5

1.8

26

1,360

770

500

120

2.0

1.2

0.5

1.8

28

1,620

880

500

150

2.0

1.2

0.5

1.8

29

1,920

990

500

185

2.0

1.2

0.5

1.9

31

2,300

1,150

500

240

2.0

1.2

0.5

1.9

33

2,890

1,380

500

300

2.0

1.2

0.5

2.0

36

3,510

1,610

500

400

2.0

1.2

0.5

2.1

37

4,380

1,950

500

d

630

2.4

1.3

0.5

2.4

47

7,000

2,970

500

Three-core, CU/XLPE/STA/PVC vel AL/XLPE/STA/PVC (Tabula 18)

Conductor

Nominal

Area

Insulation Crassitudo

Proxime.Interiorem Coverage

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

10

2.0

1.2

0.5

1.8

28

910

720

500

16

2.0

1.2

0.5

1.9

29

1,120

820

500

25

2.0

1.2

0.5

1.9

32

1,480

1,000

500

35

2.0

1.2

0.5

2.0

35

1,840

1,170

500

50

2.0

1.2

0.5

2.1

38

1,300

1,410

500

70

2.0

1.2

0.5

2.2

43

3,390

2,100

500

95

2.0

1.2

0.5

2.3

46

4,330

2,530

500

120

2.0

1.3

0.5

2.4

50

5,180

2,910

500

150

2.0

1.4

0.5

2.6

54

6,180

3,370

500

185

2.0

1.4

0.5

2.7

57

7,120

3,920

500

240

2.0

1.5

0.5

2.8

63

9,350

4,750

400

300

2.0

1.6

0.5

3.0

68

11,340

5,550

300

400

2.0

1.8

0.5

3.3

76

14,220

6,830

300

500

2.2

1.9

0.5

3.5

84

17,850

8,380

250

3.6/6(7.2)kV,XLPE Insulis PVC Insulis

Single-core, CU/XLPE/PVC vel AL/XLPE/PVC (Tabula 19)

Conductor

Nominal

Area

Insulation Crassitudo

Exterior Vagina Crassitudo

Proxime.

Super

Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

kg/km

m

10

2.5

1.8

15

320

260

500

16

2.5

1.8

18

390

290

500

25

2.5

1.8

20

500

340

500

35

2.5

1.8

21

610

400

500

50

2.5

1.8

22

750

450

500

70

2.5

1.8

24

970

550

500

95

2.5

1.8

25

1,250

660

500

120

2.5

1.8

27

1,500

760

500

150

2.5

1.8

28

1,790

860

500

185

2.5

1.9

30

2,150

1,000

500

240

2.6

1.9

33

2,770

1,250

500

300

2.8

2.0

35

3,400

1,500

500

400

3.0

2.1

39

4,280

1.850

500

500

3.2

2.2

43

5,400

2,280

500

630

3.2

2.4

47

6,830

2,800

500

800

3.2

2.5

51

8,570

3,400

400

1,000

3.2

2.6

56

10,590

4,110

300

Core, CU/XLPE/PVC vel AL/XLPE/PVC (Tabula XX)

Conductor

Nominal

Area

Insulation Crassitudo

Exterior Vagina Crassitudo

Proxime.

Super

Diameter

Proxime.Cable Pondus

Latin Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

kg/km

m

10

2.5

1.9

33

980

790

500

16

2.5

2.0

35

1,190

890

500

25

2.5

2.1

38

1,560

1,080

500

35

2.5

2.2

40

1,930

1,270

500

50

2.5

2.3

43

2,370

1,480

500

70

2.5

2.4

47

3,110

1,820

500

95

2.5

2.5

51

4,000

2,200

500

120

2.5

2.6

54

4,820

2,550

500

150

2.5

2.7

58

5,770

2,970

500

185

2.5

2.8

61

6,960

3,460

500

240

2.6

3.0

68

8,940

4,340

400

300

2.8

3.2

73

10,980

5,190

300

400

3.0

3.5

81

13,820

6,440

250

500

3.2

3.7

90

17,390

7,910

200

3.6/6(7.2)kV,XLPE filum armatum PVC vaginatum Power Cable

Single-core, CU/XLPE/AWA/PVC orAL/XLPE/AWA/PVC (Tabula 21)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

10

2.5

1.2

0.9

1.8

22

610

550

500

16

2.5

1.2

1.6

1.8

24

680

580

500

25

2.5

1.2

1.6

1.8

25

810

660

500

35

2.5

1.2

1.6

1.8

26

940

730

500

50

2.5

1.2

1.6

1.8

27

1,100

810

500

70

2.5

1.2

1.6

1.8

29

1,350

930

500

95

2.5

1.2

1.6

1.9

31

1,670

1,080

500

120

2.5

1.2

1.6

1.9

32

1,950

1,200

500

150

2.5

1.2

1.6

2.0

34

2,270

1,350

500

185

2.5

1.2

2.0

2.1

37

2,770

1,620

500

240

2.6

1.2

2.0

2.2

40

3,440

1,930

500

300

2.8

1.2

2.0

2.2

42

4,120

2,210

500

400

3.0

1.3

2.5

2.4

47

5,250

2,820

500

500

3.2

1.3

2.5

2.5

51

6,450

3,340

500

630

3.2

1.4

2.5

2.6

55

7,990

3,950

400

Three-core, CU/XLPE/SWA/PVC or AL/XLPE/SWA/PVC (Tabula 22)

Conductor

Nominal

Area

Insulation Crassitudo

Proxime.Interiorem Coverage

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

10

2.5

1.2

2.0

2.1

40

2,310

2,120

500

16

2.5

1.2

2.0

2.2

42

2,600

2,290

500

25

2.5

1.2

2.0

2.3

45

3,080

2,600

500

35

2.5

1.3

2.5

2.4

48

3,950

3,280

500

50

2.5

1.3

2.5

2.5

54

4,530

3,630

500

70

2.5

1.4

2.5

2.6

55

5,510

4,210

500

95

2.5

1.5

2.5

2.8

59

6,660

4,860

500

120

2.5

1.5

2.5

2.9

63

7,630

5,360

400

150

2.5

1.6

2.5

3.0

66

8,800

6,000

400

185

2.5

1.7

3.15

3.2

72

11,500

6,670

300

240

2.6

1.8

3.15

3.4

78

13,480

8,870

250

300

2.8

1.9

3.15

3.6

84

15,920

10,130

200

400

3.0

2.0

4.0

3.9

94

21,300

12,590

200

500

3.2

2.1

4.0

4.1

103

25,090

15,610

200

Cable

Single-core, CU/XLPE/ATA/PVCor AL/XLPE/ATA/PVC (Tabula 23)

Conductor

Nominal

Area

Insulation Crassitudo

Proxime.Interiorem Coverage

Crassitudo

Armor

Filum

Magnitudo

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

10

2.5

1.2

0.5

1.8

22

530

460

500

16

2.5

1.2

0.5

1.8

23

600

500

500

25

2.5

1.2

0.5

1.8

24

730

570

500

35

2.5

1.2

0.5

1.8

25

850

630

500

50

2.5

1.2

0.5

1.8

26

1,000

700

500

70

2.5

1.2

0.5

1.8

28

1,240

820

500

95

2.5

1.2

0.5

1.8

30

1,540

950

500

120

2.5

1.2

0.5

1.8

31

1,820

1,080

500

150

2.5

1.2

0.5

1.9

33

2,120

1,200

500

185

2.5

1.2

0.5

1.9

35

2,520

1,370

500

240

2.6

1.2

0.5

2.0

37

3,180

1,670

500

300

2.8

1.2

0.5

2.1

40

3,850

1,950

500

400

3.0

1.3

0.5

2.3

44

4,800

2,370

500

500

3.2

1.3

0.5

2.4

48

5,960

2,840

500

630

3.2

1.4

0.5

2.5

52

7,450

3,410

600

Three-core, CU/XLPE/STA/PVCor AL/XLPE/STA/PVC (Tabula 24)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

10

2.5

1.2

0.2

2.0

37

1,330

1,140

500

16

2.5

1.2

0.5

2.1

40

1,580

1,580

500

25

2.5

1.2

0.5

2.2

42

2,310

1,880

500

35

2.5

1.3

0.5

2.3

45

2,760

2,090

500

50

2.5

1.3

0.5

2.4

48

3,260

2,360

500

70

2.5

1.4

0.5

2.5

52

4,100

2,810

500

95

2.5

1.5

0.5

2.7

56

5,110

3,310

500

120

2.5

1.5

0.5

2.8

60

5,010

3,750

400

150

2.5

1.6

0.5

2.9

63

7,050

4,250

400

185

2.5

1.7

0.5

3.0

67

9,320

4,820

400

240

2.6

1.8

0.5

3.2

73

10,530

5,920

300

300

2.8

1.9

0.5

3.4

79

12,730

6,940

300

400

3.0

2.0

0.8

3.7

89

16,620

9,240

200

500

3.2

2.1

0.8

4.0

98

20,550

11,070

200

6 ~ 30kV XLPE Insulae Power Cables

  • Hoc productum utitur Finnia Nextrom(NOKIA) trium ordinum co-extrusionis linea productionis ad fabricam chemicam transversalem.

  • Medii lineae intentionis ad certam impositionem apta est.

  • Funes facere secundum stipulationem IEC 60502 .

Specification of Products

Model

Nomen

CU/XLPE/PVC

AL/XLPE/PVC

Aeris vel Aluminium Conductor XLPE Insulated et PVC infusa Power Cable

CU/XLPE/PE

AL/XLPE/PE

Aluminium Conductor XLPE Insulated et PE de potentia Cable infusa

CU/XLPE/STA/PVC

AL/XLPE/STA/PVC

Aeris vel Aluminium Conductor XLPE Insulated Steel Tape Armored PVC

CU/XLPE/STA/PE

AL/XLPE/STA/PE

Aeris vel Aluminium Conductor XLPE Insulated Steel Tape Armored PE vaginatus Power Cable

CU/XLPE/SWA/PVC

AL/XLPE/SWA/PVC

Aeris vel Aluminium Conductor XLPE Insulatus Steel Wire Armored PVC

CU/XLPE/SWA/PE

AL/XLPE/SWA/PE

Aeris vel Aluminium Conductor XLPE Steel Wire rmored PE vaginatus Power Cable

CU/XLPE/CWL/PE

AL/XLPE/CWL/PE

Aluminium Conductor XLPE Insulated Comprehensive Waterproof Layer Power Cable

Range applicationis

Model

Range applicationis

CU/XLPE/PVC

AL/XLPE/PVC

Domes et foris aptum est, bracket in cuniculo figi debet et per fistulam concretam deferri vel in fossa fune conlocari et in solo resoluto directe defosso.Funem impressionem sustinere non potest, sed quodam radiorum tractu permittit.

CU/XLPE/PE

AL/XLPE/PE

CU/XLPE/STA/PVC

AL/XLPE/STA/PVC

Humo sepultus, funem pressionis alicuius sustinere potest, sed magnam vim distrahendi sustinere non potest.

CU/XLPE/STA/PE

AL/XLPE/STA/PE

CU/XLPE/SWA/PVC

AL/XLPE/SWA/PVC

CU/XLPE/SWA/PE

AL/XLPE/SWA/PE

CU/XLPE/CWL/PE

AL/XLPE/CWL/PE

Ponitur ad aquam resistendam postulationem tegumen funerum

East Energy

Electrical Engineering

6/6kV,6/10(12)kV,XLPE Insulae inermes PVC Vatae Power Cable Single-core, CU/XLPE/PVC vel AL/XLPE/PVC (Tabula 25)

Conductor

Nominal

Area

Insulation Crassitudo

Exterior Vagina Crassitudo

Proxime.

Super

Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

kg/km

m

16

3.4

1.8

20

450

350

500

25

3.4

1.8

21

560

400

500

35

3.4

1.8

22

680

460

500

50

3.4

1.8

24

810

520

500

70

3.4

1.8

25

1,050

620

500

95

3.4

1.8

27

1,320

730

500

120

3.4

1.8

28

1,580

840

500

150

3.4

1.9

30

1,880

960

500

185

3.4

1.9

32

2,250

1,100

500

240

3.4

2.0

34

2,870

1,350

500

300

3.4

2.1

37

3,490

1,580

500

400

3.4

2.2

40

4,350

1,920

500

500

3.4

2.3

44

5,440

2,320

500

630

3.4

2.4

48

6,860

2,830

500

800

3.4

2.5

52

8,600

3,430

400

1.000

3.4

2.6

56

10,630

4,150

300

Core, CU/XLPE/PVC vel AL/XLPE/PVC (Tabula 26)

Conductor

Nominal

Area

Insulation Crassitudo

Exterior Vagina Crassitudo

Proxime.

Super

Diameter

Approx.Cable Pondus

Latin Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

kg/km

m

16

3.4

2.1

39

1,410

1,110

500

25

3.4

2.2

42

1,800

1,320

500

35

3.4

2.3

45

2,170

1,500

500

50

3.4

2.4

47

2,630

1,730

500

70

3.4

2.5

51

3,400

2,110

500

95

3.4

2.6

55

4,310

2,510

500

120

3.4

2.7

58

5,150

2,860

500

150

3.4

2.9

62

6,100

3,300

500

185

3.4

3.0

66

7,310

3,810

500

240

3.4

3.1

71

9,290

4,680

400

300

3.4

3.3

76

11,240

5,450

300

400

3.4

3.5

83

14,040

6,660

250

500

3.4

3.7

91

17,530

8,050

200

6/6kV,6/10(12)kV,XLPE filum armatum PVC insulatum Power Cable

Single-core, CU/XLPE/AWA/PVC vel AL/XLPE/AWA/PVC (Tabula 27)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

16

3.4

1.2

1.6

1.8

26

770

670

500

25

3.4

1.2

1.6

1.8

27

910

750

500

35

3.4

1.2

1.6

1.8

28

1,040

820

500

50

3.4

1.2

1.6

1.8

29

1,190

900

500

70

3.4

1.2

1.6

1.9

31

1,470

1,040

500

95

3.4

1.2

1.6

2.0

33

1,780

1,190

500

120

3.4

1.2

2.0

2.0

35

2,150

1,410

500

150

3.4

1.2

2.0

2.1

37

2,480

1,560

500

185

3.4

1.2

2.0

2.1

39

2,890

1,730

500

240

3.4

1.2

2.0

2.2

41

3,570

2,050

500

300

3.4

1.2

2.0

2.3

44

4,230

2,330

500

400

3.4

1.3

2.5

2.4

48

5,320

2,890

500

500

3.4

1.3

2.5

2.5

52

6,500

3,380

500

630

3.4

1.4

2.5

2.6

56

8,020

3,990

400

CO/XLPE/SWA/PVC vel AL/XLPE/SWA/PVC (Tabula 28)

Conductor

Nominal

Area

Insulation Crassitudo

Proxime.Interiorem Coverage

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

16

3.4

1.3

2.5

2.4

47

3,700

2,700

500

25

3.4

1.3

2.5

2.5

50

3,900

3,430

500

35

3.4

1.3

2.5

2.6

53

4,430

3,770

500

50

3.4

1.4

2.5

2.7

56

5,080

4,190

500

70

3.4

1.5

2.5

2.8

60

6,050

4,750

500

95

3.4

1.5

2.5

2.9

64

7,180

5,380

500

120

3.4

1.6

2.5

3.0

67

8,230

5,960

400

150

3.4

1.7

3.15

3.2

72

10,100

6,580

300

185

3.4

1.7

3.15

3.3

76

11,610

8,110

300

240

3.4

1.8

3.15

3.5

82

14,110

9,510

250

300

3.4

1.9

3.15

3.7

87

16,420

10,630

200

400

3.4

2.0

4.0

4.0

96

21,700

12,880

200

500

3.4

2.2

4.0

4.2

104

25,280

15,800

200

6/6kV,6/10(12)kV,XLPE Tape armata PVC insulata Power Cable

Single-core, CU/XLPE/ATA/PVC vel AL/XLPE/ATA/PVC (Tabula 29)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Latin Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

16

3.4

1.2

0.5

1.8

25

680

580

500

25

3.4

1.2

0.5

1.8

26

810

650

500

35

3.4

1.2

0.5

1.8

27

940

720

500

50

3.4

1.2

0.5

1.8

28

1,090

790

500

70

3.4

1.2

0.5

1.9

30

1,350

920

500

95

3.4

1.2

0.5

1.9

32

1,650

1,060

500

120

3.4

1.2

0.5

2.0

33

1,940

1,190

500

150

3.4

1.2

0.5

2.0

35

2,240

1,320

500

185

3.4

1.2

0.5

2.1

37

2,650

1,500

500

240

3.4

1.2

0.5

2.1

39

3,290

1,770

500

300

3.4

1.2

0.5

2.2

41

3,940

2,030

500

400

3.4

1.3

0.5

2.3

45

4,860

2,430

500

500

3.4

1.3

0.5

2.4

49

5,990

2,880

500

630

3.4

1.4

0.5

2.5

52

7,480

3,450

500

Core, CU/XLPE/STA/PVC vel AL/XLPE/STA/PVC (Tabula 30)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Latin Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

16

3.4

1.3

0.2

2.3

44

2,220

1,900

500

25

3.4

1.3

0.5

2.4

47

2,660

2,180

500

35

3.4

1.3

0.5

2.5

50

3,110

2,440

500

50

3.4

1.4

0.5

2.6

53

3,650

2,750

500

70

3.4

1.5

0.5

2.7

56

4,510

3,220

500

95

3.4

1.5

0.5

2.8

60

5,510

3,710

500

120

3.4

1.6

0.5

2.9

64

6,450

4,180

500

150

3.4

1.7

0.5

3.1

68

7,500

4,700

400

185

3.4

1.7

0.5

3.2

71

8,830

5,330

400

240

3.4

1.8

0.5

3.3

77

10,960

6,360

300

300

3.4

1.9

0.5

3.5

82

13,090

7,300

250

400

3.4

2.0

0.8

3.8

91

16,910

9,530

200

500

3.4

2.2

0.8

4.0

99

20,720

11,250

200

8.7/10kV,8.7/15(17.5)kV,XLPE Insulae PVC Insulae Potestate Cable

Single-core, CU/XLPE/PVC vel AL/XLPE/PVC (Tabula 31)

Conductor

Nominal

Area

Insulation Crassitudo

Exterior Vagina Crassitudo

Proxime.

Super

Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

kg/km

m

25

4.5

1.8

24

640

480

500

35

4.5

1.8

25

760

540

500

50

4.5

1.8

26

900

610

500

70

4.5

1.8

28

1,140

710

500

95

4.5

1.8

29

1,420

830

500

120

4.5

1.9

31

1,700

950

500

150

4.5

1.9

32

1,990

1,070

500

185

4.5

2.0

34

2,380

1,230

500

240

4.5

2.1

37

3,010

1,490

500

300

4.5

2.1

39

3,620

1,720

500

400

4.5

2.2

42

4,490

2,070

500

500

4.5

2.3

46

5,600

2,480

500

630

4.5

2.5

50

7,050

3,010

500

800

4.5

2.6

54

8,800

3,630

400

1,000

4.5

2.7

58

10,850

4,370

300

Core, CU/XLPE/PVC vel AL/XLPE/PVC (Tabula 32)

Conductor

Nominal

Area

Insulation Crassitudo

Exterior Vagina Crassitudo

Proxime.

Super

Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

kg/km

m

25

4.5

2.4

47

2,100

1,620

500

35

4.5

2.5

50

2,510

1,840

500

50

4.5

2.6

52

2,980

2,080

500

70

4.5

2.7

56

3,760

2,470

500

95

4.5

2.8

60

4,700

2,900

500

120

4.5

2.9

63

5,590

3,320

500

150

4.5

3.0

67

6,560

3,760

500

185

4.5

3.1

71

7,800

4,300

400

240

4.5

3.3

76

9,820

5,220

300

300

4.5

3.5

81

11,800

6,010

300

400

4.5

3.7

88

14,620

7,250

250

500

4.5

3.9

96

18,150

8,680

200

8 .7/10kV,8.7/15(17.5)kV,XLPE filum armatum PVC insulatum Power Cable

Single-core, CU/XLPE/AWA/PVC orAL/XLPE/AWA/PVC (Tabula 33)

Conductor

Nominal

Area

Insulation Crassitudo

Proxime.Interiorem Coverage

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

25

4.5

1.2

1.6

1.8

29

1,020

860

500

35

4.5

1.2

1.6

1.9

30

1,170

950

500

50

4.5

1.2

1.6

1.9

32

1,340

1,040

500

70

4.5

1.2

1.6

2.0

34

1,640

1,190

500

95

4.5

1.2

2.0

2.1

36

2,020

1,430

500

120

4.5

1.2

2.0

2.1

38

2,310

1,570

500

150

4.5

1.2

2.0

2.2

39

2,660

1,740

500

185

4.5

1.2

2.0

2.2

41

3,070

1,920

500

240

4.5

1.2

2.0

2.3

44

3,750

2,240

500

300

4.5

1.3

2.5

2.4

47

4,590

2,690

500

400

4.5

1.3

2.5

2.5

50

5,550

3,120

500

500

4.5

1.4

2.5

2.6

51

6,750

3,640

500

630

4.5

1.4

2.5

2.7

58

8,280

4,240

400

Three-core, CU/XLPE/SWA/PVC or AL/XLPE/SWA/PVC (Tabula 34)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armor

Filum

Magnitudo

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Latin Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

25

4.5

1.4

2.5

2.7

55

4,560

4,080

500

35

4.5

1.4

2.5

2.8

58

5,080

4,410

500

50

4.5

1.5

2.5

2.9

61

5,740

4,840

500

70

4.5

1.6

2.5

3.0

65

6,770

5,480

500

95

4.5

1.6

2.5

3.1

69

7,890

6,100

400

120

4.5

1.7

3.15

3.2

74

10,900

6,700

400

150

4.5

1.8

3.15

3.4

77

11,030

8,220

300

185

4.5

1.8

3.15

3.5

81

12,490

8,980

250

240

4.5

1.9

4.0

3.7

89

17,500

10,440

250

300

4.5

2.0

4.0

3.9

94

20,100

12,130

200

400

4.5

2.1

4.0

4.1

101

23,600

13,970

200

Cable

Single-core, CU/XLPE/ATA/PVC vel AL/XLPE/ATA/PVC (Tabula 35)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Nullam dolor diam

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

25

4.5

1.2

0.5

1.8

28

910

760

500

35

4.5

1.2

0.5

1.8

29

1,050

830

500

50

4.5

1.2

0.5

1.9

30

1,210

920

500

70

4.5

1.2

0.5

1.9

32

1,470

1,050

500

95

4.5

1.2

0.5

2.0

34

1,790

1,200

500

120

4.5

1.2

0.5

2.0

35

2,070

1,320

500

150

4.5

1.2

0.5

2.1

37

2,400

1,470

500

185

4.5

1.2

0.5

2.1

39

2,800

1,640

500

240

4.5

1.2

0.5

2.2

41

3,460

1,940

500

300

4.5

1.3

0.5

2.3

44

4,160

2,230

500

400

4.5

1.3

0.5

2.4

47

5,050

2,620

500

500

4.5

1.4

0.5

2.5

51

6,220

3,100

500

630

4.5

1.4

0.5

2.6

55

7,710

3,670

500

Three-core, CU/XLPE/STA/PVC vel AL/XLPE/STA/PVC (Tabula 36)

Conductor

Nominal

Area

Insulation Crassitudo

Proxime.Interiorem Coverage

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

25

4.5

1.4

0.5

2.6

52

3,120

2,640

500

35

4.5

1.4

0.5

2.6

55

3,570

2,900

500

50

4.5

1.5

0.5

2.7

58

4,120

3,220

500

70

4.5

1.6

0.5

2.9

62

5,050

3,750

500

95

4.5

1.6

0.5

3.0

66

6,070

4,270

500

120

4.5

1.7

0.5

3.1

69

7,040

4,770

500

150

4.5

1.8

0.5

3.2

73

8,120

5,310

400

185

4.5

1.8

0.5

3.3

77

9,440

5,940

300

240

4.5

1.9

0.5

3.5

83

11,660

7,050

300

300

4.5

2.0

0.8

3.7

89

14,600

8,810

250

400

4.5

2.1

0.8

4.0

96

17,760

10,370

200

500

4.5

2.3

0.8

4.2

105

21,620

12,150

200

Cable

Single-core, CU/XLPE/PVC vel AL/XLPE/PVC (Tabula 37)

Conductor

Nominal

Area

Insulation Crassitudo

Exterior Vagina Crassitudo

Proxime.

Super

Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

kg/km

m

35

5.5

1.8

27

840

620

500

50

5.5

1.8

28

990

690

500

70

5.5

1.9

30

1,230

800

500

95

5.5

1.9

31

1,530

940

500

120

5.5

2.0

33

1,810

1,060

500

150

5.5

2.0

35

2,110

1,190

500

185

5.5

2.1

36

2,510

1,360

500

240

5.5

2.1

39

3,130

1,610

500

300

5.5

2.2

41

3,760

1,860

500

400

5.5

2.3

44

4,650

2,220

500

500

5.5

2.4

48

5,760

2,650

500

630

5.5

2.5

52

7,210

3,180

500

800

5.5

2.6

56

8,980

3,800

400

1,000

5.5

2.8

61

11,060

4,580

300

Three-core, CU/XLPE/PVC vel AL/XLPE/PVC

38

Conductor

Nominal

Area

Insulation Crassitudo

Exterior Vagina Crassitudo

Proxime.

Super

Diameter

Proxime.Cable Pondus

Latin Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

kg/km

m

35

5.5

2.6

54

2,850

2,080

500

50

5.5

2.7

57

3,340

2,450

500

70

5.5

2.9

61

4,150

2,850

500

95

5.5

3.0

65

5,110

3,310

500

120

5.5

3.1

68

5,990

3,730

500

150

5.5

3.2

72

6,980

4.180

500

185

5.5

3.3

75

8,240

4,740

400

240

5.5

3.5

81

10,310

5,700

300

300

5.5

3.6

86

12,350

6,570

300

400

5.5

3.8

93

15,220

7,830

200

500

5.5

4.1

101

18,800

9,320

200

Cable

Single-core, CU/XLPE/AWA/PVC orAL/XLPE/AWA/PVC (Tabula 39)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

35

5.5

1.2

1.6

1.9

32

1,290

1,070

500

50

5.5

1.2

2.0

2.0

35

1,550

1,250

500

70

5.5

1.2

2.0

2.1

37

1,840

1,420

500

95

5.5

1.2

2.0

2.1

38

2,160

1,570

500

120

5.5

1.2

2.0

2.2

40

2,470

1,730

500

150

5.5

1.2

2.0

2.2

41

2,810

1,890

500

185

5.5

1.2

2.0

2.3

43

3,240

2,090

500

240

5.5

1.3

2.5

2.4

47

4,100

2,580

500

300

5.5

1.3

2.5

2.5

49

4,800

2,890

500

400

5.5

1.4

2.5

2.6

53

5,780

3,350

500

500

5.5

1.4

2.5

2.7

57

6,970

3,850

500

630

5.5

1.5

2.5

2.8

60

8,540

4,500

400

Three-core, CU/XLPE/SWA/PVCorAL/XLPE/SWA/PVC (Tabula 40)

Conductor

Nominal

Area

Insulation Crassitudo

Approx.Inner Cover

Crassitudo

Armatura filum Size

Exterior

Vagina

Crassitudo

Proxime.Super Diameter

Proxime.Cable Pondus

Standard

Longitudo Per

Drum

Copper

aluminium

mm²

mm

mm

mm

mm

mm

kg/km

m

35

5.5

1.5

2.5

2.9

63

5,680

5,010

500

50

5.5

1.6

2.5

3.0

66

6,370

5,480

500

70

5.5

1.7

2.5

3.1

70

7,370

6,070

400

95

5.5

1.7

3.15

3.3

75

9,400

7,600

300

120

5.5

1.8

3.15

3.4

79

10,530

8,270

300

150

5.5

1.8

3.15

3.5

82

11,740

8,940

300

185

5.5

1.9

3.15

3.7

86

13,350

9,850

250

240

5.5

2.0

4.0

3.9

94

18,000

11,820

200

300

5.5

2.1

4.0

4.0

99

20,500

13,080

200

400

5.5

2.2

4.0

4.3

106

23,310

15,930

200