Self-auxilio LV-ABC Lineae

Codicis:   ABC0.6/1kV,NFA2X,AsXS(n),1-AES.

Signa: HD 626 S1:1996 Pars IV-SectionF, PL WT92/K396;

CSN 34761-4F.

Constructio: Phase Conductores: Aluminium conductores cum XLPE insulation

Neutrale Messenger: Aluminium conductores cum XLPE velit.

Applicatio:  Conductores aerei Bundled pro reticulis tributariis aedificiorum potentiae et retiacula interna adhibentur.

Installation: Hae rudentes non licet etiam in ductibus sepeliri.

Dimensiones Phase Conductores

Cross Section

Conductor

Diameter

Crassitudo

Insulation

Core Diameter

Current Capacitas baiulans

Fractio

Load

(mm²)

min.

max.

nom.

min.

min

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)

16

4.6

5.1

1.2

1.00

7.8

2.60

25

5.6

6.5

1.3

1.07

10.1

107

4.17

35

6.6

7.5

1.3

1.07

11.0

132

5.78

50

7.7

8.6

1.5

1.25

12.5

165

8.45

70

9.3

10.2

1.5

1.25

14.0

205

11.32

95

11.0

12.0

1.7

1.50

16.1

15.30

120

12.5

13.5

1.8

1.60

17.6

20.00

150

13.9

15.0

1.8

1.60

18.8

25.00

* Definitur temperatus ambientium ex 35° et max.conductoris temperatus 80°℃.

Dimensiones Neutrales Conductores

Numerus Phase Cores Crucis Sectio + Public Lighting Conductors

+Neutralis Crucis Section

(mm²)

Fasciculus Diameter

Proxime.

(mm)

2×16

15

2×25

18

2×35

20

4×16

18

4×25

22

4×35

25

4×50

28

4×70

32

4×70+1×35

36

4×70+2×35

40

4×95

37

4×120

40

4×120+2×35

43

4×150

44

Codex: ABC 0.6/1kV.

Standards: HD 626  S1:1996  Part5-Section D,AMKA(SFS     MMCC).

Constructio: Phase  Conductores: Aluminium conductores cum XLPE velit.

Neutrale Messenger: Aluminium conductores.

Applicationem: Conductores aerei Bundled pro reticulis tributariis aedificiorum potentiae et retiacula interna adhibentur.

Institutionem: Hi rudentes etiam in specubus sepeliri non licet.

Dimensions of* Phase Conductores

Cross Section

Conductor

Diameter

Crassitudo Insulation

Core Diameter

Current Capacitas baiulans

Fractio

Load

(mm²)

min.

tolerantia

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)

16

4.4

±0.05

1.4

7.1

7.3

70

25

5.9

±0.02

1.4

8.3

9.1

95

35

6.9

±0.02

1.6

9.7

10.5

115

50

8.1

±0.25

1.6

10.8

11.8

140

70

9.7

±0.25

1.8

12.8

13.8

180

120

12.8

±0.30

2.0

16.2

17.4

250

*  definitum  for*  ambientium  temperatus  of 25℃  et  max.conductor  temperatus  of 70℃.

Cross Section

Conductor Diameter

Crassitudo Insulation

Core Diameter

Current Capacitas baiulans

Fractio Load

(mm²)

min.

tolerantia

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)

25

5.9

±0.02

5.5

6.3

7.4

35

6.9

±0.02

6.5

7.3

10.3

50

8.1

±0.25

7.6

8.6

14.2

70

9.7

±0.25

9.2

10.2

20.6

95

11.4

±0.30

10.8

12.0

27.9

Dimensions     of*     Cable     Fasciculus

Numerus Phase Cores Crucis Sectio + Public Lighting Conductors

+ Neutrale Crucis Section

(mm²)

Fasciculus Diameter

Proxime.

(mm)

1×16+25

15

3×16+25

22

4×16+25

22

3×25+35

26

4×25+35

26

3×35+50

30

3×50+70

35

3×70+95

41

3×120+95

47

LV-ABC Lineae cum Messenger Neutrali Insulated

Codex: ABC 0.6/1kV.

Signa:HD 626 S1:1996 Pars VI-Section E, AMKA(SFS 2200)

Construction: Aluminium conductores cum XLPE  velit.

Applicationem: Aerial Bundled Conductores pro retis potentiae tributariae adhibentur     edificiis et retis internis.

Installation: Hos rudentes sepeliri non licet, etiam in ductibus.

Dimensions of* Phase Conductores

Cross Section

Conductor

Diameter

Crassitudo

Insulation

Core Diameten

Current Capacitas baiulans

Fractio Load

(mm²)

min.

max.

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)

16

4.6

5.1

1.2

7.0

7.8

25

5.8

6.3

1.4

8.6

9.4

112

35

6.8

7.3

1.6

10.0

10.9

138

50

7.9

8.4

1.6

11.1

12.0

168

70

9.7

10.2

1.8

13.3

14.2

213

95

11.0

12.0

1.8

14.6

15.7

258

120

12.0

13.1

1.8

15.6

16.7

306

150

13.9

15.0

1.7

17.3

18.6

344

* Defined pro temperie ambientium 30℃ et max.conductor temperatus 90℃.

Dimensions of* Neutrale Nuntius Conductores

Cross Section

Conductor

Diameter

Crassitudo

Insulation

Core Diameter

Current Capacitas baiulans

Fractio

Load

(mm²)

min.

tolerantia

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)

54.6

9.2

9.6

1.6

12.3

13.0

16.6

70

10.0

10.2

1.5

12.9

13.6

20.5

95

12.2

12.9

1.6

15.3

16.3

27.5

* Definitur temperatus ambientium 30℃ et max.conductor temperatus 90℃.

Dimensions of * Cable  Fasciculus

Numerus Phase Cores Crucis Sectio + Public Lighting Conductors

+Neutralis Crucis Section

(mm²)

Fasciculus Diameter

Proxime.

(mm)

3×25+54.6

30.0

3×35+K×16+54.6

33.0

3×50+K×16+54.6

36.0

3×70+K×16+54.6

37.5

3×70+K×25+54.6

40.0

3×70+K×16+70

41.0

3×95+K×16+70

44.0

3×120+K×16+70

46.0

3×120+K×16+95

47.0

3×150+K×16+70

48.0

3×150+K×16+95

49.0

* Nota: K numerus conductorum publicorum conductorum (K potest esse = 0.1.2.or 3).

Codex: ABC 11kV.

Signa: SANS MDCCXIII.

Constructio: Phase  Conductores: Aluminium conductores cum XLPE velit.

Neutrale  Nuntius: A  destitutus  galvanized  chalybe  conductor  cum  Nulla XLPE.

Applicatio: Bundled Conductores aerei ad continuos idoneos

operatio foris in tropicis locis ad altitudinem usque ad 2200m super mare

planities, humiditas usque ad 90%, mediocris ambiens temperatus +30℃ cum

minimum - 1℃ et maximum of +4℃ in direct  sol, gravis

SAL  conditionibus  per '  the  oram  et  isoceraunic  levels  de sursum  to  180

dies tonitribus per annum.

Installation: Hos rudentes sepeliri non licet, etiam in ductibus.

Phase Conductor Characteres

1

Conductor    magnitudine

mm²

70

95

185

2

Diameter    super '    conductor.nominal

mm

9.3-10.2

11.6

16.4

3

Crassitudo   of*   dielectric.nominal

mm

3.4

3.4

3.4

Minimum  at  a  punctum

mm

2.96

2.96

2.96

4

Diameter  super '  velit.  nominal

mm

16.1-17.0

21.3

25.9

5

Diameter  super '  semi-ducendi  core  latebra.  nominal

mm

18.1-19

23.3

27.9

6

Crassitudo  of*  cuprum  tape.nominal

mm

0.15

1.15

2.15

7

Crassitudo   of*   sheath.nominal

mm

1.8

1.8

1.8

Minimum  at  a  punctum

mm

1.43

1.43

1.51

8

Catenary   magnitudine

mm²

50

50

70

9

Super   diametri   of*   bundle.nominal

mm

55.7

67.8

79.2

10

Nominal  mass

kg/m

2.64

3.25

4.65

Catenary Characteres supporting

1

Catenaria magnitudine

mm²

50

70

2

Pluribus filis

7

7

3

Magnitudine filum (diam)

mm

3.0

3.6

4

Minimum distrahentes vires uniuscuiusque filum

kN

9.26

13.13

5

Elongation at break.minimum

%

3.5

4.0

6

Crassitudo tutelae velamen

Nominal

mm

1.2

1.2

Minimum ad punctum

mm

0.96

1.96

7

Impusewhsandvoag        e1.250s

21kV/5min

21kV/5min

priorem: 
deinde: 

DE NOBIS

Societas nostra professionalis societas est quae exercetur in productione, venditionibus, investigationibus technicis, technicis evolutionis et technicis servitiis electrica systematis productorum, potentia machinalis, consiliorum et constructionis, electrica productorum, electrica instrumentorum, venditionum, institutionis et technicae servitutis instrumenti energiae repono.

ORIGINAL LINKS

PRODUCTS

NOBIS LOQUERE

2201-7&2201-8, Dongjiu Aedificium, No.888 Jiefang Orientem Road, Yixing urbem, Provinciam Jiangsu
  +86-18020528228
  +86-510-87015096
   +86-====/+86-18761555908
Copyright © 2023 Jiangsu East Energy Electrical Engineering Co., Ltd. Technology by Leadong. Sitemap.