In domo » Productus » Cables » Power funem » Aluminium Conductors cum xlpe Vallum ad caput potentia linea applications

Aluminium Conductors cum xlpe Vallum ad caput potentia linea applications

Aerial bundled Conductors (ABC) sunt insulated caput potentia distribution systems disposito tutum et efficient electricity tradenda in urbana, rusticus, et industriae areas. Dissimilis traditional nudum conductores, ABC systems fasciculo plures insulatas tempus Conductors cum neutrum vel nuntius filum, reducendo installation costs, obscuratis conditionibus et enhancing in dura tempestate, et enhancing in dura tempestatum.
Cross Sectional Area;
Availability:
quantitas;
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • ABC

P Roduct d Escription


conductor

Applications

- Rustica Electrift: Specimen pro remotis locis cum limited infrastructure.

- Urbana distribution: caput lineae in dense populosiorem zonas.

- arboribus zonis: ignis repugnans et Eco-amica.

- Industrial Complexes: Reliable Power Supple in dura environments.

- Renewable Energy: Coniungit Solaris / Ventus Rerumque ad Grids.

Features

Weatherproof, resistit UV, pluvia, nix et pollutio.

-Safety, reducitur periculo brevi circuitus et accidentalis contactus.

-Low sustentationem: minimal sagging et corrosio.

-Space, salute: Paperback Design reduces recta-of-via requisita.

-Easy installation: Pre-Pre-Bundled ad celeri deplowent.

Signa

- IEC (LX) DII (Power Cables ad XXX KV)

- IEC (LXI) LXXXIX (Circularis concentricis lay Stranded Conductors)

- ASTM B232 (Aluminium Conductors, Concentric-laicus-Stranded)

- BS (VII) DCCCLXX (LV et MV Polymeric Insulated Cables)

- sicut / NZs MMMDLX (Australia / New Zealand signa ad ABC)

Constructio

I. Conductors: summus puritas Aluminium aut Aluminium Aluminium (Aaac) ad tempus et neutrum fila.

II. Valet, crucem, coniunctum polyethylene (xlpe) aut summus density polyethylene (HDPE) pro UV et humorem resistentia.

III. Nuntius fili: libitum ferro aut aluminium mixle core ad mechanicas firmamentum.

IV. Bundling: Phase Conductors et neutrum sunt retorta et tenetur simul cum durabile UV repugnans tapes.

Clavis parametri

- Voltage Rating: 0.6 / I KV (LV) seu XI KV / XXXIII KV (Mv)

- Conductor magnitudinum: XVI mmq ad CCXL MM⊃2; (Aluminium)

- Temperature range: -40 ° C XC ° C (Operational)

- Current facultatem: usque ad DC a, fretus configuratione.

Technical notitia

Res

Valor

SINTULATIO

1.5 mm - 3.5 mm (xlpe / hdpe)

Tensile vires

1000-1500 N / mm² (Nuntius Wire)

Resistentia

1,12 Ω / km (pro L mm² al)

Pondus

150-600 kg / km (variatur per magnitudine)




Code: ABC 0.6 / 1KV.

Signa: HD DCXXVI  S1: MCMXCVI  part5-section D, Amka (SFS     MMCC).

Construction: Phase  Conductors: Aluminium Conductors cum xlpe Nulla.

Nuntius neutrum: Aluminium Conductors.

Application : aeria bundled Conductors sunt in tributarius retiacula potestas aedificia et internum networks.

Installation: Hae rimores non liceat sepulti, etiam in condits.

Dimensiones Phase Conductors

Crucem sectionem

Conductor

Diameter

Crassitudine in Vallis

Core diameter

Vena portantes facultatem

Praevaricatio

Onus

(Mm²)

min.

tolerantia

Nom.

min.

min.

Max.

(A *)

(KN)

(M)

(M)

(M)

(M)

(M)


16

4.4

± 0.05

1.4


7.1

7.3

70


25

5.9

± 0.02

1.4


8.3

9.1

95


35

6.9

± 0.02

1.6


9.7

10.5

115


50

8.1

± 0.25

1.6


10.8

11.8

140


70

9.7

± 0.25

1.8


12.8

13.8

180


120

12.8

± 0.30

2.0


16.2

17.4

250


*  Defined  pro  ambientium  temperatus  de XXV ℃  et  max.conductor  temperatus  de LXX ℃.

Crucem sectionem

Conductor diameter

Crassitudine in Vallis

Core diameter

Vena portantes facultatem

Solveret onus

(Mm²)

min.

tolerantia

Nom.

min.

min.

Max.

(A *)

(KN)

(M)

(M)

(M)

(M)

(M)


25

5.9

± 0.02



5.5

6.3


7.4

35

6.9

± 0.02



6.5

7.3


10.3

50

8.1

± 0.25



7.6

8.6


14.2

70

9.7

± 0.25



9.2

10.2


20.6

95

11.4

± 0.30



10.8

12.0


27.9

Dimensiones     cable     fascis    

Numerus of Phase Cores × crucem sectioni + publico dolor Conductors

+ Neutral Cross section

(Mm²)

Fascis diameter

Proxime.

(M)

I × XVI + XXV

15

III × XVI + XXV

22

IV × XVI + XXV

22

III × XXV + XXXV

26

IV × XXV + XXXV

26

III × XXXV + L

30

III × L + LXX

35

III × LXX + XCV

41

III × CXX + XCV

47

LV-ABC lineas cum insulatas neutrum nuntius

Code: ABC 0.6 / 1KV.

Signa: HD DCXXVI S1: MCMXCVI Pars VI-section E, Amka (SFS MMCC)

Construction: Aluminium Conductors cum xlpe  velit.

Application: aeria bundled Conductors sunt in tributarius retiacula potestas     aedificia et internum networks.

Installation: Hae rimores non liceat sepulti, etiam in condits.

Dimensiones Phase Conductors

Crucem sectionem

Conductor

Diameter

Crassitudo

Initium

Core diameten

Vena portantes facultatem

Solveret onus

(Mm²)

min.

Max.

Nom.

min.

min.

Max.

(A *)

(KN)

(M)

(M)

(M)

(M)

(M)


16

4.6

5.1

1.2


7.0

7.8



25

5.8

6.3

1.4


8.6

9.4

112


35

6.8

7.3

1.6


10.0

10.9

138


50

7.9

8.4

1.6


11.1

12.0

168


70

9.7

10.2

1.8


13.3

14.2

213


95

11.0

12.0

1.8


14.6

15.7

258


120

12.0

13.1

1.8


15.6

16.7

306


150

13.9

15.0

1.7


17.3

18.6

344


* Defined pro ambientium temperatus de XXX ℃ et max. Conductor temperatus de XC ℃.

Dimensiones neutrum Messenger Conductors

Crucem sectionem

Conductor

Diameter

Crassitudo

Initium

Core diameter

Vena portantes facultatem

Praevaricatio

Onus

(Mm²)

min.

tolerantia

Nom.

min.

min.

Max.

(A *)

(KN)

(M)

(M)

(M)

(M)

(M)


54.6

9.2

9.6

1.6


12.3

13.0


16.6

70

10.0

10.2

1.5


12.9

13.6


20.5

95

12.2

12.9

1.6


15.3

16.3


27.5

* Defined pro ambientium temperatus de XXX ℃ et max.conductor temperatus de XC ℃.

Dimensiones cable fascis  

Numerus of Phase Cores × crucem sectioni + publico dolor Conductors

+ Neutral Cross section

(Mm²)

Fascis diameter

Proxime.

(M)

III × XXV + 54,6

30.0

III × XXXV + K × XVI + 54,6

33.0

III × L + K × XVI + 54,6

36.0

III × LXX + K × XVI + 54,6

37.5

III × LXX + K × XXV + 54,6

40.0

III × LXX + K × XVI + LXX

41.0

III × XCV + K × XVI + LXX

44.0

III × CXX + K × XVI + LXX

46.0

III × CXX + K × XVI + XCV

47.0

III × CL + K × XVI + LXX

48.0

III × CL + K × XVI + XCV

49.0

* Nota: K numerus publico lucting Conductors (K potest esse aequalis ad 0.1.2.Or III).

Code: 11kv ABC.

Signa: Sans MDCCXIII.

Construction: Phase  Conductors: Aluminium Conductors cum xlpe Nulla.

Nuntius  neutrum  :  Galvanized  Steel  conductor  cum  xlpe.

Applicationem: Aerial Bundled Conductors et idoneam continua

Opera foris in tropicae areas ad altitudines usque ad 2200m super mare

Level, humiditas usque ad XC%, mediocris ambientium temperatus de + XXX ℃ cum

A minimum - I ℃ et maximum ex + IV ℃ in directum  solis, gravibus

SAL  Conditionibus  per  oram  et  isoceraunic  campester  of  usque  ad  180

Tonitruales diebus per annum.

Installation: Hae rimores non liceat sepulti, etiam in condits.


Phase Conductor characteres

1

Conductor    magnitudine

mm²

70

95

185

2

Diametrum    super    conductor.nominal

mm

9.3-10.2

11.6

16.4


3

Crassitudine   dielectric.nominalinal   ​

mm

3.4

3.4

3.4

Minimum  ad  punctum  ​

mm

2.96

2.96

2.96

4

Diametrum  in Nulla  .  nominal

mm

16.1-17.0

21.3

25.9

5

Diametrum  in  semi-faciendi  core  screen.  nominal

mm

18.1-19

23.3

27.9

6

Crassitudine  aeris  tape.nominal  ​

mm

0.15

1.15

2.15


7

Crassitudine   sheath.nominal   ​

mm

1.8

1.8

1.8

Minimum  ad  punctum  ​

mm

1.43

1.43

1.51

8

Caenarius   magnitudine

mm²

50

50

70

9

Altiore   diametrum   bundle.nominal   ​

mm

55.7

67.8

79.2

10

Nominal  Missam

kg / m

2.64

3.25

4.65


Supporting catenaria characteres

1

Caenarius magnitudine

mm²

50

70

2

Numerus filis


7

7

3

Filum magnitudine (diameter)

mm

3.0

3.6

4

Minimum tensile vires cuiusque filum

kn

9.26

13.13

5

Elongationem ad confractus. minimum

%

3.5

4.0


6

Crassitudine tutela operimentum




Nominal

mm

1.2

1.2

Minimum ad punctum

mm

0.96

1.96

7

E.250s        impunewhsandVoag


21kv / 5min

21kv / 5min


priorem: 
deinde: 
Ut in tactu nobiscum

DE NOBIS

Nostrum comitatu est professional turba, quae versantur in productionem, Sales, technology investigationis, technology progressionem et technica officia of electrica ratio products, potentia engineering et constructione, electrica products, electrica Services of Energy Storage apparatu et technical Services of Energy, Installation et Technical Services of Energy Storage apparatu et technical Services of Energy, Installation et Technical Services of Energy repono apparatu et technical Services of Energy, Installation et Technical Services of Energy Storage apparatu et technica.

QUICK LINKS

PRODUCTUS

CONTACT US

2201-7 & 2201-8, Dongjiu aedificium, No.888 Jiefang Oriente Road, Yixing City, Jiangsu Province
   +86-18761555908
  +86-510-87015096
    +86-18020528228/+86-18761555908   gm@4e-energy.com
Copyright © 2025 Jiangsu East Energy Electrical Engineering Co., Ltd. , 苏ICP备16064163号-1 Technology ab Leadong. Sitemap.