In domo » Productus » Cables » Power funem » ABC Overhead Power Cable, 0.6/1kV, IEC & Signa Britannica

ABC Overhead Power Cable, 0.6/1kV, IEC & Signa Britannica

5 0 Recensiones
Hoc 0,6 / 1KV Aerial Bundled funem (ABC) Meets Stersent Britannia et IEC signa, offering robust solutio ad architecturae et urbana caput potentia systems. Disposito salus et adaptability, integrata seamlessly in environments requiring minima visual impulsum et maximum reliability.
Availability:
quantitas;
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button


Aerial Bundled Cable (ABC) - IEC & British Standard Compliant

Product Description

Aerea Bundled Cable (ABC) obsecundantia cum IEC et signis Britannicis est solutionis solutionis rerum novarum supra caput potentiae dispositae ad electricitatem transmissionis tutae et efficientis in locis frequentissimis.

Haec cable ratio constat ex pluribus conductoribus insulatis connexis cum durabili ligamine externo, pacta, tempestas resistens conventus creantis, quae periculum contactuum ac brevium circuitionum minuit.

Ductores typice fiunt aluminii vel aeris puritatis altae, secundum applicationes postulationes, et cum insulantur;

  • Cross-coniunctae polyethylene (XLPE) - pro superioribus electricae et mechanicae

  • Polyethylene (PE) - ad sumptus efficens effectus

Signa obsequium

Standard Description
IEC 60228 Conductores e rudentibus insulatis
BS 7870 Aeria bundled funibus ad caput distributionis

Hoc efficit convenientiam cum craticulis globalis potentiae, dum strictae saluti et perficiendi criteriis adhaerens.

Key Design Beneficia

  • Nulla inter gradus additional opus Reducitur

  • Propius conductor iustae - spatium efficens officinae

  • Specimen pro urbanis fundis ubi supra caput lineae simul sunt;

    • aedificia

    • Arbores

    • Alia infrastructure


Key features

Aucta salus

  • Plene insulatas conductores tollere directum contactum periculum

  • Reduces electrica accidentia ad:

    • Pedestres

    • operarii

    • Cervus

  • Regium tempus ut- tempus vitia causatur:

    • Rami arboris

    • Obstantia

    • Res externae

Spatium Optimization

  • Foedus bundled compages permittit pro angustioribus ius-of-via requisitis

  • Specimen pro urbana areas cum stricto spatio

  • Potest institui in altitudine inferiori quam institutio systemata open-conductoris

  • Improves aesthetic convenientiae cum urbana landscapes

Princeps Mechanica virtus

  • Materia obligatio resistit;

    • Fortis ventis

    • Gravis nivis

    • onerat glacies

  • Ductores insulatae resistunt;

    • Abrasion

    • Corrosio chemica

  • Prostrata vita muneris

Obsequio signa

  • Certified IEC et signa Britanniae

  • Rigor probatio:

    • Electrical Conductivity

    • Nulla resistentia

    • Flamma retardatio

Minimum Sustentacionem

  • Plane inclusum consilium reducit;

    • Saepe inspectiones

    • Reparationibus

  • Nulla tuetur conductores a damnum environmental

  • Inferior lifecycle costs comparari traditional caput lineae


Applications

Applicationem Description
Residentiales Areas Potentia tuta distributio, minimizet casus periculum ne ramis incidentibus vel contactu aedificando
Industriae Zonae Vis certa officinarum et machinarum gravis - pulvis, humoris, vaporum chemicorum resistit
Regiones maritimae Corrosio repugnans velit et ligans - apta ad ambitus aeris summus sal
Montanus / Provocatus Ager, Areas Consilium fasciculum reducit ictum ventorum et locorum inaequalium
Railway & Transit Systems Potestates supra caput lineae ad impedimenta et trams - tuta, solutio spatium efficax

Technica cubits

Conductor Construction

Nominal Area (mm²) Number/Dia. ) Insulation Crassitudo (mm
1×16+16 VII / 1.70 1.30
2×16+16 VII / 1.70 1.30
3×16+16 VII / 1.70 1.30
IV × XVI VII / 1.70 1.30
1×25+25 VII / 2.10 1.30
2×25+25 VII / 2.10 1.30
3×25+25 VII / 2.10 1.30
IV × XXV VII / 2.10 1.30
1×35+35 VII / 2.50 1.30
2×35+35 VII / 2.50 1.30
3×35+35 VII / 2.50 1.30
IV × XXXV VII / 2.50 1.30
1×50+50 VII / 3.0 1.50
3×50+50 VII / 3.0 1.50
1×70+70 XIX / 2.10 1.50
3×70+70 XIX / 2.10 1.50
3×95+95 XIX / 2.50 1.60

Component Summarium

Component specificationem
Phase Conductors Aluminium Alloy Core + PE / xlpe Nulla
Nuntius neutrum Aaac aut galvanized Steel Strand (libitum)
Fascis Design Auto-supporting aut neutrum-sustinetur variants
Libitum cororum Auxiliarii cores ad lucendis / imperium systems

Faq

Q: Utrum ratio ABC adhiberi potest ad applicationes tam humilis et altae intentionis?
A: Ita. Praesto est in voltagenarum generibus ab 1kV ad 36kV, ad retiacula distribuenda in variis fundis apta.

Q: Quomodo fasciculum afficit funem scelerisque effectus?
A: Consilium scelerisque considerationes administrationis includit, et materias insulationes magno calore resistunt ut operandi in tuto limites currentes aestimantur.

Q: Estne materia ligatura UV repugnans?
A: Ita. Ligatio facta est ex polymerorum UV stabilita quae degradationem impediunt ab diuturna expositione lucis, ut diuturnum tempus servetur integritas structurae.

Q: Utrum ABC ratio requirit institutionem specialem apparatu?
A: Vexillum supra caput linea instrumenta institutionis adhiberi possunt, quamquam formatio in technicis fasciculis commendatur ut conductor recte spatii et tensionis curet.

applicatio

stipare


Code: ABC 0.6 / 1KV.

Signa: HD DCXXVI  S1: MCMXCVI  part5-section D, Amka (SFS     MMCC).

Construction: Phase  Conductors: Aluminium Conductors cum xlpe Nulla.

Nuntius neutrum: Aluminium Conductors.

Application : aeria bundled Conductors sunt in tributarius retiacula potestas aedificia et internum networks.

Installation: Hae rimores non liceat sepulti, etiam in condits.

Dimensiones Phase Conductors

Crucem sectionem

Conductor

Diameter

Crassitudine in Vallis

Core diameter

Vena portantes facultatem

Praevaricatio

Onus

(Mm²)

min.

tolerantia

Nom.

min.

min.

Max.

(A *)

(KN)

(M)

(M)

(M)

(M)

(M)


16

4.4

± 0.05

1.4


7.1

7.3

70


25

5.9

± 0.02

1.4


8.3

9.1

95


35

6.9

± 0.02

1.6


9.7

10.5

115


50

8.1

± 0.25

1.6


10.8

11.8

140


70

9.7

± 0.25

1.8


12.8

13.8

180


120

12.8

± 0.30

2.0


16.2

17.4

250


*  Defined  pro  ambientium  temperatus  de XXV ℃  et  max.conductor  temperatus  de LXX ℃.

Crucem sectionem

Conductor diameter

Crassitudine in Vallis

Core diameter

Vena portantes facultatem

Solveret onus

(Mm²)

min.

tolerantia

Nom.

min.

min.

Max.

(A *)

(KN)

(M)

(M)

(M)

(M)

(M)


25

5.9

± 0.02



5.5

6.3


7.4

35

6.9

± 0.02



6.5

7.3


10.3

50

8.1

± 0.25



7.6

8.6


14.2

70

9.7

± 0.25



9.2

10.2


20.6

95

11.4

± 0.30



10.8

12.0


27.9

Dimensiones     cable     fascis    

Numerus of Phase Cores × crucem sectioni + publico dolor Conductors

+ Neutral Cross section

(Mm²)

Fascis diameter

Proxime.

(M)

I × XVI + XXV

15

III × XVI + XXV

22

IV × XVI + XXV

22

III × XXV + XXXV

26

IV × XXV + XXXV

26

III × XXXV + L

30

III × L + LXX

35

III × LXX + XCV

41

III × CXX + XCV

47

LV-ABC lineas cum insulatas neutrum nuntius

Code: ABC 0.6 / 1KV.

Signa: HD DCXXVI S1: MCMXCVI Pars VI-section E, Amka (SFS MMCC)

Construction: Aluminium Conductors cum xlpe  velit.

Application: aeria bundled Conductors sunt in tributarius retiacula potestas     aedificia et internum networks.

Installation: Hae rimores non liceat sepulti, etiam in condits.

Dimensiones Phase Conductors

Crucem sectionem

Conductor

Diameter

Crassitudo

Initium

Core diameten

Vena portantes facultatem

Solveret onus

(Mm²)

min.

Max.

Nom.

min.

min.

Max.

(A *)

(KN)

(M)

(M)

(M)

(M)

(M)


16

4.6

5.1

1.2


7.0

7.8



25

5.8

6.3

1.4


8.6

9.4

112


35

6.8

7.3

1.6


10.0

10.9

138


50

7.9

8.4

1.6


11.1

12.0

168


70

9.7

10.2

1.8


13.3

14.2

213


95

11.0

12.0

1.8


14.6

15.7

258


120

12.0

13.1

1.8


15.6

16.7

306


150

13.9

15.0

1.7


17.3

18.6

344


* Defined pro ambientium temperatus de XXX ℃ et max. Conductor temperatus de XC ℃.

Dimensiones neutrum Messenger Conductors

Crucem sectionem

Conductor

Diameter

Crassitudo

Initium

Core diameter

Vena portantes facultatem

Praevaricatio

Onus

(Mm²)

min.

tolerantia

Nom.

min.

min.

Max.

(A *)

(KN)

(M)

(M)

(M)

(M)

(M)


54.6

9.2

9.6

1.6


12.3

13.0


16.6

70

10.0

10.2

1.5


12.9

13.6


20.5

95

12.2

12.9

1.6


15.3

16.3


27.5

* Defined pro ambientium temperatus de XXX ℃ et max.conductor temperatus de XC ℃.

Dimensiones cable fascis  

Numerus of Phase Cores × crucem sectioni + publico dolor Conductors

+ Neutral Cross section

(Mm²)

Fascis diameter

Proxime.

(M)

III × XXV + 54,6

30.0

III × XXXV + K × XVI + 54,6

33.0

III × L + K × XVI + 54,6

36.0

III × LXX + K × XVI + 54,6

37.5

III × LXX + K × XXV + 54,6

40.0

III × LXX + K × XVI + LXX

41.0

III × XCV + K × XVI + LXX

44.0

III × CXX + K × XVI + LXX

46.0

III × CXX + K × XVI + XCV

47.0

III × CL + K × XVI + LXX

48.0

III × CL + K × XVI + XCV

49.0

* Nota: K numerus publico lucting Conductors (K potest esse aequalis ad 0.1.2.Or III).

Code: 11kv ABC.

Signa: Sans MDCCXIII.

Construction: Phase  Conductors: Aluminium Conductors cum xlpe Nulla.

Nuntius  neutrum  :  Galvanized  Steel  conductor  cum  xlpe.

Applicationem: Aerial Bundled Conductors et idoneam continua

Opera foris in tropicae areas ad altitudines usque ad 2200m super mare

Level, humiditas usque ad XC%, mediocris ambientium temperatus de + XXX ℃ cum

A minimum - I ℃ et maximum ex + IV ℃ in directum  solis, gravibus

SAL  Conditionibus  per  oram  et  isoceraunic  campester  of  usque  ad  180

Tonitruales diebus per annum.

Installation: Hae rimores non liceat sepulti, etiam in condits.


Phase Conductor characteres

1

Conductor    magnitudine

mm²

70

95

185

2

Diametrum    super    conductor.nominal

mm

9.3-10.2

11.6

16.4


3

Crassitudine   dielectric.nominalinal   ​

mm

3.4

3.4

3.4

Minimum  ad  punctum  ​

mm

2.96

2.96

2.96

4

Diametrum  in Nulla  .  nominal

mm

16.1-17.0

21.3

25.9

5

Diametrum  in  semi-faciendi  core  screen.  nominal

mm

18.1-19

23.3

27.9

6

Crassitudine  aeris  tape.nominal  ​

mm

0.15

1.15

2.15


7

Crassitudine   sheath.nominal   ​

mm

1.8

1.8

1.8

Minimum  ad  punctum  ​

mm

1.43

1.43

1.51

8

Caenarius   magnitudine

mm²

50

50

70

9

Altiore   diametrum   bundle.nominal   ​

mm

55.7

67.8

79.2

10

Nominal  Missam

kg / m

2.64

3.25

4.65


Supporting catenaria characteres

1

Caenarius magnitudine

mm²

50

70

2

Numerus filis


7

7

3

Filum magnitudine (diameter)

mm

3.0

3.6

4

Minimum tensile vires cuiusque filum

kn

9.26

13.13

5

Elongationem ad confractus. minimum

%

3.5

4.0


6

Crassitudine tutela operimentum




Nominal

mm

1.2

1.2

Minimum ad punctum

mm

0.96

1.96

7

E.250s        impunewhsandVoag


21kv / 5min

21kv / 5min


priorem: 
deinde: 
Ut in tactu nobiscum

De nobis

Nostrum comitatu est professional turba, quae versantur in productionem, Sales, technology investigationis, technology progressionem et technica officia of electrica ratio products, potentia engineering et constructione, electrica products, electrica Services of Energy Storage apparatu et technical Services of Energy, Installation et Technical Services of Energy Storage apparatu et technical Services of Energy, Installation et Technical Services of Energy repono apparatu et technical Services of Energy, Installation et Technical Services of Energy Storage apparatu et technica.
 

PRODUCTUS

CONTACT US

continenti Sinarum officium
2201-7 & 2201-8, Dongjiu Aedificium, No.888 Jiefang Orientem Road, Yixing urbem, Jiangsu Provinciae, China
+ 86-510-87013147
Hong Kong officium
plana A, VII / F., Annking Industrial aedificium, XXII Wang Yip Street Oriente, Yuen diu, NT, Hong Kong
+ 852-84960208
Copyright © 2025 Energy Electrical Engineering Orientalis Co., Ltd. 苏ICP备16064163号-1 Technologia per Leadong . Sitemap.